Section [186]
Whenever using one of the special disarming features, the control panel can send the report code to the
central station, identifying how the system was disarmed.
C
ANCEL
 A
UTO
-
ARM
: A partition is disarmed during the Timed Auto-Arm's 60-second Exit Delay (see 
page 28). Only reports if Disarming Reporting Options (see page 40) are set to always report disarming. 
R
EMOTE
 D
ISARM
: System is disarmed using   the   Winload software.                                                                                                                        
K
EYSWITCH
 D
ISARMING
: System disarmed using a keyswitch (see page 22).
• Future use
8.2.5
Z
ONE
 A
LARM
 R
EPORT
 C
ODES
Sections [187] to [190]
A report code can be programmed for each of the 16 available zones. Whenever a zone generates an
alarm, the control panel can send the appropriate report code to the central station, identifying which zone
generated an alarm.
8.2.6
Z
ONE
 A
LARM
 R
ESTORE
 R
EPORT
 C
ODES
Sections [191] to [194]
A report code can be programmed for each of the 16 available zones. The control panel can transmit these
report codes to the central station identifying which zone was restored. 
A zone is restored when it closes after generating an alarm or once the bell has cut-off after alarm
generation. Please refer to Zone Restore Report Options on page 40. 
8.2.7
S
PECIAL
 A
LARM
 R
EPORT
 C
ODES
Sections [195] and [196]
Whenever the system generates an alarm due to one of the conditions listed below, the control panel can
send the appropriate report code to the central station identifying the type of alarm.
Section [195]
E
MERGENCY
 P
ANIC
: Panic keys [1] and [3] have been pressed (see page 31).
A
UXILIARY
 P
ANIC
: Panic keys [4] and [6] have been pressed (see page 31).
F
IRE
 P
ANIC
:
 Panic keys [7] & [9] have been pressed (see page 31).
R
ECENT
 C
LOSING
: Reports when an alarm is generated after arming the system within period defined 
by the Recent Close Delay (see page 39).
Section [196]
A
UTO
 Z
ONE
 S
HUTDOWN
: A zone communicates more than the programmed number of transmissions 
in a single armed period (see page 24). 
D
URESS
: A Duress access code is keyed in (see page 18). 
K
EYPAD
 L
OCKOUT
: If a consecutive number of invalid codes are entered into a keypad, the control 
panel can be set to deny access from all keypads for a specified period.
• Future use
8.2.8
Z
ONE
 T
AMPER
 R
EPORT
 C
ODES
Section [197] to [200]
A report code can be programmed for each of the 16 available zones. Whenever a tamper or wire fault
occurs on a zone, the control panel can send the appropriate report code to the central station identifying
which zone was tampered.
8.2.9
Z
ONE
 T
AMPER
 R
ESTORE
 R
EPORT
 C
ODES
Sections [201] to [204]
A report code can be programmed for each of the 16 available zones. Whenever a tampered zone is
restored, the control panel can send the appropriate report code to the central station identifying which
zone has been restored.
If Tamper Recognition (see page 30) is disabled, the control panel will not report the occurrence of
any tampers, wire faults or tamper restores.