Quattro DC Utility U0 Menu 
 
The following three different screens are used 
by the password function: 
 
 
NOTE:  Remember that a valid password must 
be entered at the ENTER PASSWORD screen 
before the password lockout condition can be 
changed. 
The HIDDEN ITEMS sub-menu allows the user 
to select whether or not “hidden” parameters 
will be displayed on the Digital Operator.  
There are two types of parameters, standard 
and hidden.  Standard parameters are 
available at all times.  Hidden parameters are 
available only if activated.   The default for this 
function is ENABLED (meaning the hidden 
parameters are visible).   
Detailed Description 
PASSWORD  
(Password Function)
   
•  ENTER PASSWORD 
•  NEW PASSWORD 
•  PASSWORD LOCKOUT 
Password Function 
The password function allows the user to 
select a six-digit number for a password. The 
password function allows the user to lockout 
changes to the parameters until a valid 
password is entered. 
And with the password lockout enabled, all 
parameters and display values will be able to 
be viewed but no changes to the parameters 
will be allowed until a correct password is 
entered. 
Parameter Protection 
If the password lockout is enabled, the 
following message will appear on the display 
when attempting to change a parameter.   
 
 
 
 
 
 
 
In order to change a parameter after password 
lockout has been enabled, the following two 
steps must be followed in the PASSWORD 
sub-menu: 
1) A valid password must be entered in the 
ENTER PASSWORD screen. 
2) The password lockout must be DISABLED 
in the PASSWORD LOCKOUT screen. 
PASSWORD Sub-menu Protection 
The following message will appear when in the 
PASSWORD sub-menu, if you are trying to: 
•  Enable or disable the password lockout 
without a valid password being entered. 
•  Enter a new password without a valid 
password being entered. 
 
 
  
 
 
 
 
ENTER PASSWORD Screen 
This screen allows the user to enter in a 
password.  A valid password must be entered 
before enabling or disabling the password 
lockout or changing to a new password. 
NEW PASSWORD Screen 
This screen is used to change the established 
password. 
NOTE:  Remember that a valid password must 
be entered at the ENTER PASSWORD screen 
before the established password can be 
changed. 
PASSWORD LOCKOUT Screen 
This screen is used to enable and disable 
password lockout.  The factory default for 
password lockout is DISABLED. 
HIDDEN ITEMS  
(Hidden Items Function) 
RUN/FAULT 
SUB MENU 
DATA ENT 
Password 
Protected 
UNITS  
(Units Selection Function) 
When the UNITS SELECTION sub-menu is 
displayed, the user can choose either Metric 
units or Standard English measurements units 
for use by the drive’s parameters. 
IMPORTANT 
The unit’s selection must be made before 
entering any setting values into the 
parameters.  The user cannot toggle between 
units after drive has been programmed. 
OVERSPEED TEST  
(Overspeed Test Function) 
The speed command is normally limited by 
Overspeed Level parameter (OVERSPEED 
LEVEL(A1)), which is set as a percentage of 
the contract speed (100% to 150%). But in 
order to allow overspeed tests during elevator 
inspections, a means is provided to multiply 
the speed command by the Overspeed 
Multiplier parameter (OVERSPEED 
MULT(A1)). 
RUN/FAULT 
SUB MENU 
DATA ENT 
PLEASE ENTER 
PASSWORD FIRST 
71