Magnetek TM7310rev01 Benutzerhandbuch

Seite von 126
Quattro DC Troubleshooting 
 
Name Description 
Possible Causes & Corrective Action 
Overvolt Flt 
 
The DC bus voltage has 
exceeded the maximum 
allowed value. 
 
Low Input Voltage 
 
Check INPUT L-L VOLTS (A5) and UV FAULT 
LEVEL (A4) 
 
Verify proper input voltage and increase, if 
necessary, the input AC voltage within the 
proper range 
 
Check for missing input phase 
 
Check power line disturbances due to starting 
of other equipment 
Line Converter Problem 
 
Verify the line converter did not shutdown 
while the motor controller was in process of 
regeneration 
Check Parameter Settings 
 
Bad tuning of either the motor side regulators 
Contactor Problem 
 
Verify motor contactor did not open while 
motoring 
Ovrtemp Alarm 
(alarm) 
 
One or more of the IGBT 
modules on the drive side 
power bridge has exceeded 
95
°C (203°F). 
Excessive Heat 
 
Check for cooling fan failure 
 
Reduce Ambient Temperature 
 
Clean heat sink 
The revision level for 
parameter data shared 
between the line side and 
motor side processors does 
not match. 
Software Incompatibility 
Param rev 
 
 
Contact Factory 
PCU data Flt 
 
PCU parameters checksum is 
invalid on the motor side. 
Parameters Corrupted 
 
Check parameters and power cycle 
 
If re-occurs, replace Main Control PCB A2 
Ready, Waiting 
For Drive 
(operator) 
 
The operator is waiting to 
establish communications with 
the drive’s control board. 
Normal, if displayed momentarily 
 
No action is required, if the message 
disappears shortly after power-up of the 
operator 
Bad Connector Connection 
 
Remove and re-seat the operator in its cradle 
 
If re-seating of the operator does not work, the 
operator may need to be replaced 
Reverse Tach 
See ENCODER FLT 
See ENCODER FLT 
S-Chain Event 
(alarm) 
 
Elevator Safety Chain opened 
while the drive was running. 
Safety Chain Problem 
 
Safety Chain was opened during a run 
 
Verify correct Safety-Chain operation and 
timing 
Setup Fault 4 
 
This fault is declared if the 
contract motor speed (in rpm) 
and encoder pulses/revolution 
do not satisfy: 
0
,
000
,
18
000
,
300
⎟⎟
⎜⎜
pulses
encoder
speed
motor
contract
 
Check Parameters Settings: 
 
Check ENCODER PULSES (A1) parameter for 
correct setting 
 
Check CONTRACT MTR SPD (A1) parameter 
for correct setting 