MASTER LOCK LTR8-512M Benutzerhandbuch

Seite von 68
LTRx-512 Installation and User’s Guide 
Wiring Diagrams 
54 
Fig. D7 – COMMUNICATION TERMINAL BLOCK
 
 
 
 
Rear of Display Unit 
 
NOTES: 
1. Twisted-pair (Cat-3/Cat-5) wire connects directly to Terminal Block; up to 2 wires per position 
2. Pulse-sync input is same as provided in power supply. One (1) second (min.) dry-contact switch closure 
across terminals causes Master to reset time to 12:00AM of nearest date 
3. Grounds (GND) are “signal grounds”, 
not “chassis grounds” 
4. Load on non-regulated 12VAC output 
must be less than 250mA 
5. For DDC4R communications, the LTRx-512 automatically sets itself as a master or slave 
 
 
Strain Relief for the Communications Cable 
 
• 
Using  the  two  wire  tie  wraps  included  in  the 
installation  kit,  attach  them  to  the  terminal  block 
as  shown  in  this  sample  to  provide  strain  relief  to 
the  communications  cable.  Use  any  two  empty 
positions. 
 
 
 
 
 
Use the six (6) connections as follows: