LTRx-512 Installation and User’s Guide 
Wiring Diagrams 
56 
Fig. D8 - POWER SUPPLY TERMINAL BLOCKS 
 
 
 
 
 
NOTES: 
 
1.
  Circuits CKT1...CKT4 designate bell controls. Circuit pairs CKT5/CKT6 and CKT7/CKT8 can function as 
clock synchronization circuits or as bell controls  
(Note: CKT1…CKT4 do not exist on the LTR4-512. Instead use CKT5…CKT8 which are indicated related to 
the LEDs on the Display Unit numbered 1-4). 
2.  MOV’s (Metal-Oxide Varistors) protect all relay contacts  
3.  Voltage-select jumpers connect to terminal block P4 for 120VAC operation. Users who need to run at 
220/240VAC 
must remove the 120V jumpers and install one jumper wire for the 240V selection. The 
system will automatically adjust for operation at 60Hz or 50Hz at either voltage 
4.  Some clock setups may require external diodes or MOV’s. See the wiring diagram for your type clock