Nortel Networks 4050 Benutzerhandbuch
628 Chapter 12 Configuring SNMP
320818-A
The event menu includes the following options:
/cfg/sys/adm/snmp/event
followed by:
addmonitor
[<options>] -b <name>
<OID> <op> <value>
[<options>] -b <name>
<OID> <op> <value>
Adds a boolean monitor and trigger as defined in the
DISMAN-EVENT-MIB.
DISMAN-EVENT-MIB.
Valid <
options
> are:
•
-c <comment>
— adds a comment
•
-f <frequency>
— the sampling interval, in
seconds. The default is 600 (10 minutes).
•
-o <OID>
— additional objects to send in the
event
•
-e <EventName>
— the name of a notification
event
•
-d <OID>
— the delta discontinuity OID
•
-D timeTicks|timeStamp|dateAndTime
— the delta discontinuity type
Other parameters are:
•
name
— a unique name you assign to the monitor,
for identification
•
OID
— the object identifier (or symbolic name) to
monitor
•
op
— the operator. Valid options are:
!= (not equals), == (equals), <= (less than or equal
to), >= (greater than or equal to), < (less than), >
(greater than)
to), >= (greater than or equal to), < (less than), >
(greater than)
•
value
— an integer indicating the value against
which the operation will be performed