Nortel Networks 4050 Manuel D’Utilisation

Page de 922
628 Chapter 12 Configuring SNMP
320818-A
 
The event menu includes the following options:
/cfg/sys/adm/snmp/event
followed by:
addmonitor 
[<options>] -b <name
<OID> <op> <value>
Adds a boolean monitor and trigger as defined in the 
DISMAN-EVENT-MIB. 
Valid <
options
> are:
-c <comment>
 — adds a comment
-f <frequency>
 — the sampling interval, in 
seconds. The default is 600 (10 minutes).
-o <OID>
 — additional objects to send in the 
event
-e <EventName>
 — the name of a notification 
event
-d <OID>
 — the delta discontinuity OID
-D timeTicks|timeStamp|dateAndTime
 
— the delta discontinuity type
Other parameters are:
name
 — a unique name you assign to the monitor, 
for identification
OID
 — the object identifier (or symbolic name) to 
monitor
op
 — the operator. Valid options are:
!= (not equals), == (equals), <= (less than or equal 
to), >= (greater than or equal to), < (less than), > 
(greater than)
value
 — an integer indicating the value against 
which the operation will be performed