Moxa Technologies 5400 Series Benutzerhandbuch

Seite von 104
NPort 5400 Series User’s Manual   
Web Console Configuration
 
 
5-25
Reverse Telnet Mode 
 
TCP alive check time 
Setting 
Factory Default 
Necessity 
0 to 99 min 
Optional 
Specifies the time slice for checking if the TCP connection is alive. If no response, the NPort 5400 will 
disconnect the original connection. 
Inactivity time 
Setting 
Factory Default 
Necessity 
0 to 65535 ms 
Optional 
Idle time setting for auto-disconnection. 0 min. means it will never disconnect. 
Local TCP port 
Setting 
Factory Default 
Necessity 
1 to 65535 
4001 
Optional 
Each of the NPort’s serial ports is mapped to a TCP port. To avoid conflicts with TCP ports, set port 
numbers to 4001 for port1, 4002 for port 2, etc. (like the default values). 
Map <CR-LF> 
Setting 
Factory Default 
Necessity 
CR, LF, or CR-LF 
CR-LF 
Optional 
If data received through the NPort 5400’s Ethernet port is sent using the “enter” command, the data will 
be transmitted out the serial port with an added 
(1) “carriage return + line feed” if you select the <CR-LF> option 
 
(i.e., the cursor will jump to the next line, and return to the first character of the line) 
(2) “carriage return” if you select the <CR> option 
 
(i.e., the cursor will return to the first character of the line) 
(3) “line feed” if you select the <LF> option. 
 
(i.e., the cursor will jump to the next line, but not move horizontally)