Lancom Systems 821 Benutzerhandbuch

Seite von 82
LANCOM 821 ADSL/ISDN – LANCOM 1621 ADSL/ISDN – LANCOM 1711 VPN
 Chapter 9: Troubleshooting
73
EN
tested (e.g. “DSL1” or “LAN-1”). Pay attention to the correct spelling of the
interfaces. Start the test for the specified interface by clicking on Execute.  
Change then to menu item Expert configuration 
 Status 
 LAN statis-
tics 
 Cable test results. The results of the cable test for the individual
interfaces are show up in a list.
The following results can occur:
OK: Cable plugged in correctly, line ok.
open with distance “0m”: No cable plugged in or interruption within less
than 10 meters distance. 
open with indication of distance: Cable is plugged in, but defect (short-
circuited) at the indicated distance.
Impedance error: The pair of cables is not terminated with the correct
impedance at the other end.