Juniper Networks M10i Benutzerhandbuch

Seite von 240
9.
Use one of the following methods to bring the PIC online:
Press and hold the PIC offline button until the status LED on the PIC faceplate
indicates normal functioning, which usually takes about 5 seconds. The LED
is usually green; for more information, see the M10i Internet Router PIC Guide.
The offline button for each PIC is located on the HCM and is labeled with
the PIC slot number. The PICs in FPC 
0
 are located on the upper HCM, and
the PICs installed in FPC 
1
 are located on the lower HCM.
Issue the following CLI command:
user@host>request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the JUNOS System Basics and
Services Command Reference
.
The normal functioning status LED confirms that the PIC is online. You can also
verify correct PIC functioning by issuing the 
show chassis fpc pic-status
 command
Figure 36: Installing a PIC
Replacing PIC Cables
Removing and installing PIC cables does not affect router function, except that a PIC
does not receive or transmit data while its cable is disconnected. To replace a PIC
cable, perform the following procedures:
Removing a PIC Cable
To remove a PIC cable, follow this procedure:
Replacing PIC Cables
101
Chapter 13: Replacing Hardware Components