 5  Updating firmware
Several processors control the flow of data in the ATTO iPBridge. The firmware to control these 
processors can easily be upgraded in the field.
The iPBridge firmware is distributed as an .ima file 
can be obtained from the ATTO Technology, Inc. web 
site at 
 or from the CD included 
with your iPBridge.
CAUTION
CAUTION
Before beginning this procedure, ensure 
that all I/O to the iPBridge has stopped.
During this procedure, do not interrupt the 
flash process. 
Do not power down the host or the 
iPBridge until the display returns the 
Ready prompt. 
Interrupting the flash process will make 
your iPBridge inoperable and you must 
return it to ATTO Technology for repair. 
Using ATTO ExpressNAV
1
If you have not already, open an ExpressNAV 
session. For instructions, refer to 
.
2
Click on the Firmware page.
3
Click Browse and locate the firmware you 
downloaded from the website or from the CD.
A sample filename: 
c:\bridge_firmware\ibrg0370.ima
4
Click Upload and wait until a success message 
is displayed.
5
Click the Restart link.
6
Click on Restart.
Using FTP 
1
Establish an FTP link to the bridge that is to be 
flashed. 
2
Use  the  PUT command to download the 
firmware file. A sample filename: 
c:\bridge_firmware\ibrg0370.ima
3
Once the download is complete, cycle power on 
the iPBridge to activate the new firmware.