1.2 System components
D410
Commissioning Manual, 08/2008 Edition
Commissioning Manual, 08/2008 Edition
17
PROFINET
SIMOTION D410 PN can communicate via PROFINET interface to the following
components:
Table 1-3
Components on PROFINET
Components
Function
The master computer (at
company and production
management level)
... communicates with other devices via Ethernet.
PG/PC programming device
... communicates with the SIMOTION SCOUT Engineering
Systems (ES), STEP 7 and HMI (Human Machine Interface).
SIMATIC HMI device
... is used for operator control and monitoring functions. It is not
absolutely essential for running SIMOTION D410.
Drive units with PROFINET
interface (e.g., SINAMICS S120
with CBE20)
... convert speed setpoints into signals for controlling the motor
and supply the power required to operate the motors.
SIMATIC ET 200M
Modular I/O system for control cabinet installation and high
channel densities.
SIMATIC ET 200S
Finely scalable I/O system for control cabinet installation and
particularly time-critical applications; including motor starters,
safety technology and individual grouping of load groups.
SIMATIC ET 200pro
Modular I/O system with IP65/IP67 rating for machine-related
applications with no control cabinet; with new features such as
more compact designs, integrated PROFIsafe safety technology,
PROFINET connection and live module replacement.
Gateways
•
IE/AS Interface Link PN IO for the PROFINET IO gateway to
AS Interface
•
PN/PN coupler to connect two PROFINET IO networks
Other controls (e.g., SIMOTION
or SIMATIC)
Note
Note that only one real axis can be used on a SIMOTION D410.
Note that only one real axis can be used on a SIMOTION D410.
Note
A list of all I/O modules that can currently be used with SIMOTION is available at the
A list of all I/O modules that can currently be used with SIMOTION is available at the
following link:
http://support.automation.siemens.com/WW/view/de/11886029