Maintenance
50
Indicators
Light
Status & Description
Power
Temp
Lamp
Power events
Orange
Orange
Orange
The projector has just been connected to a power 
outlet.
Orange
Off
Off
Stand-by mode
Green
Flashing
Off
Off
Powering up
Green
Off
Off
Normal operation
Orange
Flashing
Off
Off
1.
The projector needs 90 seconds to cool down as it 
was abnormally shut down without the normal 
cooling down process. 
Or
2.
The projector needs to cool for 90 seconds after 
the power is turned off.
Orange
Flashing
Off
Off
The projector has shutdown automatically. If you try to 
re-start the projector, it will shutdown again. Please 
contact your dealer for assistance.
Lamp events
Orange
Flashing
Off
Red
The projector has shutdown automatically. If you try to 
re-start the projector, it will shutdown again. Please 
contact your dealer for assistance.
Off
Off
Red
1.
The projector needs 90 seconds to cool down. 
Or
2.
Please contact your dealer for assistance.
Green
Off
Red
The lamp life has expired. Please replace the lamp.
Thermal events
Off
Red
Off
The projector has shutdown automatically. If you try to 
re-start the projector, it will shutdown again. Please 
contact your dealer for assistance.
Off
Red
Red
Off
Red
Green
Off
Red
Orange
Red
Red
Red
Red
Red
Green
Red
Red
Orange
Green
Red
Red
Green
Red
Green
Green
Red
Orange
Orange
Red
Red
Orange
Red
Green
Orange
Red
Orange
Off
Green
Red
Off
Green
Green