Summit HL-630 OPC Benutzerhandbuch

Seite von 46
 
40
 
 
Turn the power off. Hold down the exposure button, 
and turn the power on. All the lights except the ready 
light will come on. Release the exposure button. 
Press the exposure button again and hold for 10 
seconds, until the three exposure lights come on. 
Release the exposure button. Once the ready light 
comes on the counter is reset. Turn the power off 
then back on to lock in the new settings. 
 
 
 
 
 
Sharp Z30 OPC/Xerox 5220/XC520 
Series 
Xerox # 20E18410, Sharp # ZT30DR 
OEM Stated Yield: 20,000
 
 
NOTE: This procedure should be used by qualified 
technicians only! Placing the jumper wire in the 
wrong spot can damage the copier! This procedure 
should never be done with out rebuilding the drum 
unit/waste chamber first. 
 
Turn the power off. Remove the front cover; the 
main board is now visible. Place a jumper wire 
across pins 2 & 3. (Located under the variable 
resistors). Turn the copier on for 5 seconds then off. 
Remove the jumper and close up the copier. The 
counter is reset. 
 
 
 
 
 
 
Sharp Z50/Z70 OPC 
Sharp # ZT50DR, Xerox 5008 (13R50), 
5009 (13R55) 
OEM Stated Yield: 10,000 
Inside the copier on the back wall behind where the 
drum cartridge fits is a small black box. This box 
contains a mechanical counter with a lever that 
sticks out the top. Press the lever back and the 
counter is reset. (The lever doesn't move much). This 
can and should be done with the power off. The old 
style OPC cartridge came with a metal bar that you 
can set so that it protrudes from the cartridge. The 
bar would hit the lever and reset the counter. Newer 
cartridges have a small piece of black plastic that 
will hit the lever and be crushed in. These cartridges 
cannot be reset. You must manually reset the counter 
inside the copier. 
 
 
 
 
 
Sharp Z-835/ Xerox XC-800 OPC 
Cartridges 
Sharp OPC Part #  ZT81DR , Xerox OPC Part # 
13R544  
OEM Stated Yield: 20,000 
 
Both of the above cartridges are different, and not 
interchangeable but the reset procedures are the 
same.
 
(These procedures are the same for the XD-
100/AL-1000 copier OPC cartridges).
 
If the cartridge is not a "Starter cartridge", there is a 
small gear with a flag on it located on the gear side 
of the cartridge bottom right. Remove the gear and 
replace so that the flag is at the 1 O’clock position. If 
this gear is missing, the cartridge is a starter 
cartridge, and the following procedure must be used. 
 
To reset the starter cartridge, or any cartridge 
through the menu, do the following:  
 
Enter the diagnostics menu by turning the machine 
on, and within 4 seconds, press "CLEAR", 
"EXPOSURE MODE", "CLEAR", "EXPOSURE 
MODE". (EXPOSURE MODE is the button on the 
far left). All of the display will go blank. Using the 
10 and 1 buttons (copy quantity), enter "24" press 
"PRINT", enter "7" press "PRINT" again. The 
counter is now set to Zero!