Citizen Systems CT-S4000M Benutzerhandbuch

Seite von 160
— 15 —
80mm 82.5mm
58mm
→ 
→ 
InitialSettings
1
Communication condition DIP switch setting
Memory switch
OFF
setting method
setting
2
Hand shake
XON/XOFF
DTR/DSR
OFF
3
Bit length
7 bits
8 bits
OFF
4
Parity check
With parity
None
OFF
5
Parity selection
Even parity
Odd parity
OFF
6
OFF
7
ON
8
INIT
Reset
Invalid
OFF
3.6  Setting DIP Switch
CAUTION!
When using 112 paper roll, the partition is not used.
DIP switch
Interface board
mounting screws
CAUTION!
■ As for the setting of the serial interface, it gives priority to the setting of the memory
switch rather than the DIP switch as the factory default.
■ Consult with the dealer where the printer was purchased when the change of the DIP
switch setting is necessary.
3.5  Partition for Paper Roll
Selecting baud rate
Switch No.
6
7
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
38400, 57600 and 115200 bps can also be selected by a command, etc.
Switch No.
Function
ON
OFF
Baud rate selection
See Table below.
Baud Rate (bps)
At the time of shipment, this partition is not installed.
1.
Confirm that the power switch is OFF.
2.
Open the printer cover.
3.
Insert the partition into the slot and align it
with the scale inside of the printer which
meets the width of the paper roll used. When
using the 80mm or 82.5mm  wide paper roll,
set the partition by using the accessory screw.
*58 mm is only for label supporting model.
4.
Change the setting of paper width by reffering
to the section 5.2, "Manual Setting of Memory
Switch".
The DIP switch is present on the serial
interface board.
The function of each switch is as shown
below.
Partition
Partition
Scales