SATO M8460S Benutzerhandbuch
104
SATO RISC Printers
2. Command Codes
Programming Manual
Memory Card Function
Format/Field Recall
Command Structure:
<ESC>YR,aa <ESC>/D,bb,cc...c
aa:
aa:
Format number to be recalled (01-99)
bb:
Field number to be recalled (01-99)
cc...c:
Data to be placed in recalled field.
Example:
<ESC>YR,01<ESC>/D,01,99
Placement:
Immediately after <ESC>CC Slot Select command
Default:
None
Function:
To recall a field from a stored format and place new data in the field.
Input:
<ESC>A
<ESC>CC1
<ESC>YR,02<ESC>/D,01,TWO FIELDS OF<ESC>/D,02,VARIABLE
DATA
<ESC>Q1<ESC>Z
Note:
1. This command requires the Memory Card option. See your SATO
1. This command requires the Memory Card option. See your SATO
representative for details.
2. Only one format can be recalled at a time. However, multiple fields
may be recalled from the same format.
3. The number of data characters contained in the “cc...c” field can-
not exceed the value designated in the <ESC>/N Field Store com-
mand. If it does, the data will be truncated to fit the field length
defined in the Field Store Command.
mand. If it does, the data will be truncated to fit the field length
defined in the Field Store Command.