SATO RISC Printers
2. Command Codes
Programming Manual
Memory Card Function
Format/Field Recall
Command Structure:
<ESC>YR,aa <ESC>/D,bb,cc...c
aa:
Format number to be recalled (01-99)
bb:
Field number to be recalled (01-99)
cc...c:
Data to be placed in recalled field.
Example:
<ESC>YR,01<ESC>/D,01,99
Placement:
Immediately after <ESC>CC Slot Select command
Default:
None
Function:
To recall a field from a stored format and place new data in the field.
Input:
<ESC>A
<ESC>CC1
<ESC>YR,02<ESC>/D,01,TWO FIELDS OF<ESC>/D,02,VARIABLE
DATA
<ESC>Q1<ESC>Z
Note:
1. This command requires the Memory Card option. See your SATO
representative for details.
2. Only one format can be recalled at a time. However, multiple fields
may be recalled from the same format.
3. The number of data characters contained in the “cc...c” field can-
not exceed the value designated in the <ESC>/N Field Store com-
mand. If it does, the data will be truncated to fit the field length
defined in the Field Store Command.