39
RFID PPI1 Commands
IMPORTANT
For all examples make sure Label Length in the QUICK SETUP 
menu matches the physical length of the installed media.
Get Tag Unique ID
Purpose
Read the unique identification number of the RFID tag 
(embedded in the smart label).
Format
^RI 
x
^RI
Get Tag Unique ID command.
x
The field number to which the data will be 
assigned. The default is 0, and other 
acceptable values range from 1 to 9999.
Comments
The PPI1 only supports Alien Technology Class 1a 
tags, which do not have the unique identification 
numbers. Therefore, the PPI1 absorbs this command.
Set Tag Type
Purpose
Select the type of the RFID tag (embedded in the smart 
label).
Format
^RS 
x
^RS
Set Tag Type command.
x
Number assigned to the type of the tag. 
The default is 0, and other acceptable 
values range from 1 to 9999.
Comments
The PPI1 only supports Alien Technology Class 1a 
tags. There are no alternative choices. Therefore, the 