Write Tag
41
motion
Set this flag to 1 to read data from the tag 
without moving the label. The printer may 
adjust the label position while it reads 
data from the tag, but this adjustment will 
reverse before any subsequent normal 
label movement. Even if this flag is set to 
1, other commands (i.e., alpha or 
barcode) may move the label.
The default is 0.
reserved
This is a reserved flag. The PPI1 absorbs 
this number.
Comments
This command is only executed by the demand for 
data from any dynamic field. The PPI1 absorbs this 
command if there are no demands for the data.
Write Tag
Purpose
This command programs data into an RFID tag 
(embedded in the smart label).
Format
^WT 
start, retries, motion, protect, data format, 
reserved
^WT
Write Tag command.
start
Starting block location where data will be 
programmed into the RFID tag. The PPI1 
only supports Alien Technology Class 1a 
tags, which have only one 8–byte block. 
Therefore, 
start will be set to 0, 
regardless of the specified value.
retries
The number of automatic attempts to 
write data into the tag if previous writes 
failed. The PPI1 absorbs the number and 
uses the value on the control panel’s 
LCD.
motion
Set this flag to 1 to program data into the 
tag without moving the label. The printer 
may adjust the label position while it 
writes data into the tag, but this 
adjustment will reverse before any