Siemens CAZBHS Benutzerhandbuch

Seite von 38
- 19 - 
Maintenance 
 
For best results, grease should be compounded of a 
polyurea type and a good grade of petroleum oil and 
stabilized against oxidation. 
 
The frequency of relubricating bearings and the 
amount added each time depends on two factors - 
speed and service.  
 
All grease lube bearing motors will have affixed a 
plate with lubricating instructions.  The instructions on 
this plate should be followed to achieve optimum 
bearing life and to avoid consequential damage to 
rotating parts. 
 
Relubricate with the type of grease specified on the 
lubrication plate mounted on the motor, or compatible 
grease.  Mixing of non-compatible greases can cause 
bearing failure. 
 
Relubricate bearings with the proper grade of grease 
as follows: 
1.  Stop the motor and lock out the switch. 
2.  Thoroughly clean the grease inlet fitting or plug.  
If the motor has a plug, remove plug and clean 
the inlet. 
 
3.  Remove the drain plug (and overflow plug, if so 
equipped) and clean out any hardened grease. 
4.  Slowly pump the correct amount of grease into 
the grease inlet, per the lubrication plate mounted 
on the motor.  Replace inlet plug (and overflow 
plug, if so equipped). 
5.  Start motor and allow to run at least one (1) hour 
to expel any excess grease from the drain 
opening before re-installing the drain plug. 
6.  Stop the motor and lock out the switch. 
7.  Re-install the drain plug. 
8.  Put the motor back in operation. 
 
NOTE 
If unit has been in operation for several years the old 
grease can harden.  If this occurs remove bolts 
holding bottom inside end cap, raise end cap and 
wipe out hardened grease.  Reassemble and add a 
small amount of fresh grease. 
If machine is a totally-enclosed or weather-protected 
type disassembly of the lower bearing may be 
required to remove old grease.  Also  clean and refill 
inlet, overflow, and drain grease pipes. 
 
NOTE 
Because the lower  bearing is single shielded, the 
grease will not pass through the drain port unless the 
motor is run for some time. 
 
 
 
Figure 4