  Troubleshooting Procedures  
PORTEGE M780 Maintenance Manual (960-809) 
 [CONFIDENTIAL] 
2-35 
2.6  2.5” HDD Troubleshooting 
To check if the 2.5” HDD is malfunctioning or not, follow the troubleshooting procedures 
below as instructed. 
Procedure 1:  Partition Check 
Procedure 2:  Message Check 
Procedure 3:  Format Check 
Procedure 4:  Diagnostic Test Program Execution Check 
Procedure 5:  Connector Check and Replacement Check 
 
CAUTION:  The contents of the hard disk will be erased when the 2.5”HDD 
troubleshooting procedures are executed. Transfer the contents of the hard 
disk to floppy disks or other storage drive(s). For the backup, refer to the 
User’s Manual. 
2.6.1  Procedure 1 Partition Check 
Insert the Toshiba DOS system disk and start the computer. Perform the following checks:  
Check 1  Input C: and press Enter. If you cannot change to drive C, go to Check 2. If you 
can change to drive C, go to Procedure 2. 
Check 2  Input FDISK and press Enter. Choose Display Partition Information from the 
FDISK menu. If drive C is listed in the Display Partition Information, go to Check 
3. If drive C is not listed, return to the FDISK menu and choose the option to 
create a DOS partition or a logical DOS drive on drive C. If the problem still 
occurs, go to Procedure 2. 
Check 3  If drive C is listed as active in the FDISK menu, go to Check 4. If drive C is not 
listed as active, return to the FDISK menu and choose the option to set the active 
partition for drive C. Then go to Procedure 2. 
Check 4  Remove the system disk from the FDD and reboot the computer. If the problem 
still occurs, go to Procedure 2. Otherwise, the 2.5” HDD is operating normally.