9-10
Monitoring parameter registers 
Address Code 
Description 
Unit
Range 
Min. 
unit 
Read/
Write 
Data 
Format
2049 M01 
Frequency 
command 
 (final command) 
- 20000
–20000  
(max. frequency at 
± 20000) 
1 R 
[2] 
2053 M05 
Frequency 
command 
 (final command) 
Hz
0.00
–400.00 
(P11S:0.00-120.00) 
0.01 R [5] 
2054 M06 
Actual 
frequency 
- 20000
–20000 
(max. frequency at 
± 20000) 
1 R 
[2] 
2055 
M07 
Actual torque value 
- 200.00
–200.00 
0.01 R [6] 
2056 M08 
Torque 
current 
- 200.00
–200.00 
0.01 R [6] 
2057 M09 
Output 
frequency 
Hz
0.00
–400.00 
(P11S:0.00-120.00) 
0.01 R [5] 
2058 
M10 
Motor output (input 
electric power) 
0.00
–200.00 
0.01 R [5] 
2059 
M11 
Output current r. m. s. 
0.00
–200.00 (inverter rating 
at 100.00) 
0.01 R [5] 
2060 
M12 
Output voltage r. m. s. 
0.0
–600.0 
1.0 R [3] 
2061 
M13 
Operation command (final 
command) 
Refer to data format [14] 
[14] 
2062 M14 
Operating 
state 
Refer 
to data format [16] 
[16] 
2063 
M15 
Universal output terminal 
data 
Refer to data format [15] 
[15] 
2064 M16 
Fault 
memory 
2065 M17 
Fault 
memory 
2066 M18 
Fault 
memory 
2067 M19 
Fault 
memory 
Refer to data format [10]   
[10] 
2068 M20 
Integrated 
operating 
time
0
–65535 
1 R 
[1] 
2069 
M21 
DC link voltage 
0
–1000 
1 R 
[1] 
2071 
M23 
Type code 
Refer to data format [17] 
[17] 
2072 
M24 
Inverter capacity code 
Refer to data format [11] 
[11] 
2073 M25 
ROM 
version 
0
–64999 
1 R 
[1] 
2074 M26 
Transmission 
error 
processing code 
Refer to data format [20] 
[20] 
2075 
M27 
Frequency command at 
alarm (final command) 
- 20000
–20000 (max. 
frequency at 
±20000 ) 
1 R 
[2] 
2079 
M31 
Frequency command at 
alarm (final command) 
Hz
0.00
–400.00 
(P11S:0.00-120.00) 
0.01 R [5] 
2080 
M32 
Actual frequency at alarm 
- 20000
–20000 
(max. frequency at 
± 20000) 
1 R 
[2] 
2081 
M33 
Actual torque at alarm 
- 200.00 
– 200.00 
0.01 R [6] 
2082 
M34 
Torque current at alarm 
- 200.00 
– 200.00 
0.01 R [6] 
2083 
M35 
Output frequency at alarm
Hz
0.00 
– 400.00 
(P11S:0.00-120.00) 
0.01 R [5] 
2084 
M36 
Motor output at alarm 
(input power) 
0.00
–200.00 
0.01 R [5] 
2085 
M37 
Output current r.m.s. at 
alarm 
0.00 
– 200.00 (inverter rating 
at 100.00) 
0.01 R [5] 
2086 
M38 
Output voltage effective 
value at alarm 
0.0 
– 600.0 
1.0 R [3] 
2087 
M39 
Operation command at 
alarm 
Refer to data format [14] 
[14] 
2088 
M40 
Operating state at alarm 
Refer to data format [16] 
[16] 
2089 
M41 
Universal output terminal 
data at alarm 
Refer to data format [15] 
[15] 
2090 M42 
Integrated 
operation 
time 
at alarm 
0
–65535 
1 R 
[1] 
2091 
M43 
DC link voltage at alarm 
0
–1000 
1 R 
[1] 
2092 
M44 
Inverter internal air 
temp.at alarm 
°C
0
–120 
1 R 
[1] 
2093 
M45 
Cooling fin temp. at alarm
°C
0
–120 
1 R 
[1] 
2094 
M46 
Life of main circuit 
capacitor. 
0.0
–100.0 
0.1 R [3] 
2095 
M47 
Life of printed circuit 
board capacitor. 
0
–65535 
1 R 
[1] 
2096 
M48 
Life of cooling fan. 
0
–65535 
1 R 
[1]