Intel ATX12V Benutzerhandbuch

Seite von 43
ATX12V Power Supply Design Guide 
Version 2.0  
37 
5.   Environmental 
The following subsections define recommended environmental specifications and test 
parameters, based on the typical conditions to which an ATX12V power supply may be 
subjected during operation or shipment. 
5.1.   Temperature 
Operating ambient 
+10 °C to +50 °C 
(At full load, with a maximum temperature rate of change of 
 5 °C/10 minutes, but no more than 10 °C/hr.) 
Non-operating ambient 
-40 °C to +70 °C 
 
(Maximum temperature rate of change of 20 °C/hr.) 
5.2.   Thermal Shock (Shipping) 
Non-operating -40 
°C to +70 °C 
 15 
°C/min 
≤ dT/dt ≤ 30 °C/min 
Tested for 50 cycles; Duration of exposure to temperature 
extremes for each half cycle shall be 30 minutes. 
5.3.   Humidity 
Operating 
To 85% relative humidity (non-condensing) 
Non-operating 
To 95% relative humidity (non-condensing) 
 
Note:  95% RH is achieved with a dry bulb temperature of 
55 °C and a wet bulb temperature of 54 °C. 
5.4.   Altitude 
Operating 
To 10,000 ft 
Non-operating 
To 50,000 ft