Intel ATX12V Benutzerhandbuch

Seite von 43
ATX12V Power Supply Design Guide 
Version 2.0 Final Review Copy 
 
  
39 
6.   Electromagnetic Compatibility 
The following subsections outline sample product regulations requirements for a typical 
power supply.  Actual requirements will depend on the design, product end use, target 
geography, and other variables.  Consult your company’s Product Safety and Regulations 
department for more details. 
6.1.   Emissions 
The power supply shall comply with FCC Part 15, EN55022:  1998 and CISPR 22: 1997,  
meeting Class B for both conducted and radiated emissions with a 4 dB margin.  Tests shall 
be conducted using a shielded DC output cable to a shielded load.  The load shall be 
adjusted as follows for three tests:  No load on each output; 50% load on each output; 
100% load on each output.  Tests will be performed at 100 VAC 50Hz, 120 VAC 60 Hz, 
and 230 VAC 50 Hz power. 
6.2. Immunity 
The power supply shall comply with EN 55024:1998.