6.3.   Input Line Current Harmonic Content and Line Flicker  
For sales in EU (European Union) or Japan the power supply shall meet the requirements of 
EN61000-3-2 Class D and the Guidelines for the Suppression of Harmonics in Appliances 
and General Use Equipment Class D for harmonic line current content at full rated power.  
See Table 16 for the harmonic limits. 
 
Table 16.  Harmonic Limits, Class D Equipment 
 
Per:  EN 61000-3-2
 
 
Per: JEIDA MITI
 
Harmonic Order 
Maximum permissible Harmonic 
current at 230 VAC / 50 Hz in Amps 
 
Maximum permissible Harmonic 
current at 100VAC / 50 Hz in Amps 
 
Odd harmonics 
11 
13 
15
 n 
39 
2.3 
1.14 
0.77 
0.4 
0.33 
0.21 
0.15 x (15/n) 
 5.29 
2.622 
1.771 
0.92 
0.759 
0.483 
0.345 x (15/n) 
 
6.4.   Magnetic Leakage Fields 
A PFC choke magnetic leakage field should not cause any interference with a high-
resolution computer monitor placed next to or on top of the end-use chassis.