Chapter 18 Replacing a power supply 209
Installation and Maintenance Guide
Setting up the base unit
This section describes the steps for replacing a standard power supply with a redundant power 
supply. After the redundant power supply is installed, insert the two power supply modules. 
Redundant power supply modules can be changed while the system is running, as long as one of 
the modules remains active.
1
If you still have access to the Unified Manager, shut down the system using the Shutdown 
command. For details refer to 
. Otherwise, 
skip to step 2.
2
Set up the BCM1000 for maintenance, as described in 
.
3
Disconnect the power supply from the internal connections.
4
Cut the cable ties that hold the power cables to the base unit.
5
Remove the standard power supply and set aside. 
Refer to 
.
6
Remove the jumper from the connectors on the System Status Module. Refer to the following 
diagram to locate the SSM board.
The diagram below notes the location of the connectors for the redundant power supply and 
for the redundant fan.
Figure 116   System Status Monitor internal connectors
Note: 
When you upgrade to a redundant power supply, you must also put in a redundant 
SSM board
J7
J6
Mother board Redundant power supply 
monitoring cable
Mother board (J10)
Board power
Redundant/primary fans
CPU fan
Remote temperature 
sensor
Note: Chassis has all PCI 
cards removed, for clarity