Nortel Networks BCM1000 Benutzerhandbuch

Seite von 311
Chapter 2 Telephony hardware
35
Installation and Maintenance Guide
Power connections
The back of the modules have a single connector that provides a DS256 connector and power to 
the module. These connectors plug into the back of the media bay on the BCM1000 or 
BCM1000e. Some modules also have a cooling fan that runs off the module power source. 
 shows the rear views of the two types of modules.
Figure 13   Rear of modules showing DS256 and power connectors
*Red LED
On
Power converter 
failure. Power to 
telephones may not 
be within spec. 
(check base unit 
LEDs for possible 
power issue or 
replace module)
N/A
Flashing
N/A
Loss of DS256 clock, or 
DS256 cable may be 
disconnected.
* Not all modules have red LEDs
LED state
Power 
Status 
DS256 and power 
connector
DS256 and 
power connector
Cooling fan
Module wires are vul-
nerable to breakage. 