IBM Partner Pavilion BMD00082 Benutzerhandbuch

Seite von 166
SmartConnect User’s Guide
82  
„
  Chapter 6: Configuring Switch Access
BMD00082, February 2009
Apply and Save the Configuration
The apply and save commands are still needed after the last command 
(scp ad4.cfg scpadmin@205.178.15.100:putcfg). 
Or, instead, you can use the following commands:
„
The diff command is automatically executed at the end of putcfg to notify the remote 
client of the difference between the new and the current configurations.
„
putcfg_apply
 runs the apply command after the putcfg is done.
„
putcfg_apply_save
 saves the new configuration to the flash after putcfg_apply 
is done.
„
The putcfg_apply and putcfg_apply_save commands are provided because 
extra apply and save commands are usually required after a putcfg; however, a SCP 
session is not in an interactive mode at all.
SSH and SCP Encryption of Management Messages
The following encryption and authentication methods are supported for SSH and SCP:
Server Host Authentication:Client RSA authenticates the switch at the beginning of every con-
nection
Key Exchange: 
RSA
Encryption:
3DES-CBC, DES
User Authentication:
Local password authentication, RADIUS, SecurID 
(via RADIUS, TACACS+, for SSH only—does not apply to SCP)
>> # 
scp ad4.cfg scpadmin@205.178.15.157 1022:putcfg_apply
>> # 
scp ad4.cfg scpadmin@205.178.15.157 1022:putcfg_apply_save