Juniper Networks EX8208 Benutzerhandbuch

Seite von 338
7.
Flip a power supply’s
Enable
switch to the on position (ON). See Figure 71 on page 181.
Observe the power supply faceplate LEDs. If the power supply is installed correctly
and functioning normally, the
INPUT OK
/
IN OK
and
OUTPUT OK
/
OUT OK
LEDs
light and remain constantly lit. The
FAIL
LED does not light.
Figure 71: Flip the Enable Switch to the ON position
8.
Repeat Step 7 for the remaining power supplies installed in the switch.
9.
On the external management device, monitor the startup process to ensure that the
system boots properly.
NOTE: After you power on a power supply, wait for at least 60 seconds before you turn
it off. After you power off a power supply, wait for at least 60 seconds before you turn
it back on.
If the system is completely powered off when you switch on a power supply, the SRE
or RE module boots as the power supply completes its startup sequence.
After you power on a power supply, it can take up to 60 seconds for status indicators
such as power supply LEDs and the
show chassis
operational mode CLI command
display to indicate that the power supply is functioning normally. Ignore any error
indicators that might appear during the first 60 seconds.
Related Topics
Connecting an EX Series Switch to a Management Console
You can configure and manage an EX Series switch using a dedicated console. Every EX
Series switch has a console port with an RJ-45 connector. Use the console port to connect
the EX Series switch to the management console or to a console server. The console
port accepts a cable with an RJ-45 connector.
181
Copyright © 2010, Juniper Networks, Inc.
Chapter 10: Connecting the Switch