clear port advertise
D-Series CLI Reference 4-17
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to configure port 1 to advertise 1000BASE‐T full duplex: 
D2(su)->set port advertise ge.1.1 1000tfd
clear port advertise
Use this command to configure a port to not advertise a specific speed/duplex capability when 
auto‐negotiating with another port.
Syntax
clear port advertise {port-string}{10t | 10tfd | 100tx | 100txfd | 1000t | 1000tfd 
pause}
Parameters
Defaults
None.
Mode
Switch command, read‐write.
100txfd
Advertise 100BASE‐TX full duplex mode. Refer to “
” on page 4‐2 for more information on setting advertised 
ability for 100 Mb SFP tranceivers.
1000t
Advertise 1000BASE‐T half duplex mode.
1000tfd
Advertise 1000BASE‐T full duplex mode.
pause
Advertise PAUSE for full‐duplex links.
port‐string
Clear advertisements for specific port(s). For a detailed description of 
possible port‐string values, refer to 
10t
Do not advertise 10BASE‐T half duplex mode.
10tfd
Do not advertise 10BASE‐T full duplex mode.
100tx
Do not advertise 100BASE‐TX half duplex mode.
100txfd
Do not advertise 100BASE‐TX full duplex mode.
1000t
Do not advertise 1000BASE‐T half duplex mode.
1000tfd
Do not advertise 1000BASE‐T full duplex mode.
pause
Do not advertise PAUSE for full‐duplex links.