Enterasys Networks D2G124-12P Benutzerhandbuch

Seite von 496
set inlinepower trap
2-32 Basic Configuration
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the power threshold to 50 :
D2(su)->set inlinepower threshold 50 
set inlinepower trap
Use this command to enable or disable the sending of an SNMP trap message for a unit
 
whenever 
the status of its ports changes, or whenever the unit’s power usage threshold is crossed. The unit’s 
power usage threshold must be set using the set inlinepower threshold command as described on 
page 
Syntax
set inlinepower trap {disable | enable} 
Parameters
Mode
Switch command, read‐write.
Example
This example shows how to enable inline power trap messaging:
D2(su)->set inlinepower trap enable 
show port inlinepower
Use this command to display all ports supporting PoE. 
Syntax
show port inlinepower [port-string]
Parameters
Defaults
If not specified, information for all PoE ports will be displayed.
Mode
Switch command, read‐only.
disable | enable
Disables or enables inline power trap messaging.
port‐string
(Optional) Displays information for specific PoE port(s).