GarrettCom Magnum 6KQ Benutzerhandbuch
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
50
www GarrettCom com
.
.
“+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must
be connected to the post labeled “+”.
be connected to the post labeled “+”.
The connection procedure is straightforward. Simply connect the DC leads to
the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
tightened.
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
tightened.
C5.1 UL Requirements
The following must be adhered to in order to conform to UL requirements:
1. Minimum 18 AWG cable for connection to a Centralized DC power source.
2. Minimum 14 AWG cable for connection to earthing wiring.
3. Use only with Listed 10 A circuit breaker provided in building installation.
4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.”
2. Minimum 14 AWG cable for connection to earthing wiring.
3. Use only with Listed 10 A circuit breaker provided in building installation.
4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.”
or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch pound max.
6. Centralized DC Power Source cable securement, use at least four cable ties to
6. Centralized DC Power Source cable securement, use at least four cable ties to
secure the cable to the rack at least 4 inches apart with the first one located
within 6 inches of the terminal block.
within 6 inches of the terminal block.
C6.0 ORDERING
INFORMATION
To order the optional Dual-Source -48VDC power supply factory installed,
order “Dual-Src48V” as a separate line item following the product model.
order “Dual-Src48V” as a separate line item following the product model.
Example: Magnum 6KQR-48VDC
Dual-Src-48V for the regular DS model
Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a
separate line item following the product model.
separate line item following the product model.
Example:
Magnum 6KQ-24VDC or Magnum P6KQ-125VDC
Dual-Src24V
for regular models
Or Dual-Src125V-Switch
See the Configuration Guide on the GCI web site at
http://www.garrettcom.com/techsupport/insertion_guides/6kqcg.pdf
for additional information.
C7.0
OPERATION
Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC
Switch models are identical to that of the standard models.
Switch models are identical to that of the standard models.