Hearth & Home Technologies WSK300 Benutzerhandbuch

Seite von 16
1
Installation & Operating Instructions
WSK300 
Multifunction Wall Control 
2101-915G  10/08
Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be 
voided by, the following actions:
•  Installation and use of any damaged system 
component.
• Modifi cation of the system component.
•  Installation other than as instructed by Hearth & Home 
Technologies.
•  Installation and/or use of any component part not 
approved by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
•  Read, understand and follow these instructions for safe 
installation and operation.
WARNING
Introduction 
Printed in U.S.A.     Copyright 2008
Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
The WSK300 multifunctional wall switch is designed to 
control fl ame height, blower speed, and up to 2 other 110-
120 VAC auxiliary functions on your gas fi replace. Also, 
the wall switch is equipped with thermostat functions 
which can automatically control the temperature in the 
room in which it is installed. The control is only for use 
with the Intellifi re system (IPI). However, the pilot function 
can control the pilot fl ame as well.   Electrical ratings for 
the control box are 110 VAC, 60 Hz, and is required for 
operation of this device.
Installation 
1.  Locate placement of wall control. The wall control must 
be located within 30 feet (within the line of sight) of the 
fi replace and 5 feet from the fl ooring. A maximum wire 
length of 50 feet may be used.
 
 
Note: The electrical junction box provided with the fi replace 
must be wired with 110 VAC before installing this kit. See 
owners manual for details.
Shock Hazard
Do not provide any power to this unit until all 
wiring is completed. Failure to do so may destroy 
parts of this device and render it unusable, and 
may lead to possible electrical shock.
Fire Hazard
Modifi cation of any parts or installation of dama-
ged components will void the warranty, and you 
may possibly cause a fi re hazard.
2.  Remove wall control from packaging material.
3.  Remove wall control back plate by pushing down on 
two tabs located at top left and right of control face.
4.  Mount control box back on wall surface. Install two 
screws at holes provided on wall control back at top 
and bottom.
All wiring should be done by a qualifi ed  electrician  and 
shall be in compliance with local codes and with the 
National Electric Code ANSI/NFGA No. 70- current (in the 
United States), or with the current CSA C22.1 CANADIAN 
ELECTRIC CODE (in Canada).
WARNING
Note:  Whenever the fi replace is turned on, the fl ame size 
will always be on HI for 75 seconds, then the control will set 
the fl ame to the programmed setting.
Note: The wall control is a three conductor, low voltage 
control that requires a minimum of a 22 gauge wire. The 
control is shipped with 18 feet of wire.
Note:  This wall control is designed to mount to a wall 
junction box. To secure to wall properly ensure that a wall 
stud is located behind wall.  For exterior wall installations, 
it is recommended that the junction box be sealed with 
caulking material. This will minimize heat loss through 
this location and improve the accuracy of the automatic 
(thermostat) operation.
Note: Ensure wires are connected to the correct color 
coded locations on terminal block face. Red to red, green 
to green, and white to white/yellow.
5.  Connect red, green and white wires from the fi replace 
control module to the terminal block located on the 
back of the control face panel.
Placement of this wall switch may affect performance or 
accuracy of the automatic (thermostat) control. An as-
sessment of the space should be done prior to installation 
for optimal performance. See the installation instructions 
section I for recommendations.