2-1-4-1. Serial RS-232 Port 
To perform the configuration through RS-232 console port, the switch’s serial 
port must be directly connected to a DCE device, for example, a PC, through      
RS-232 cable with DB-9 connector. Next, run a terminal emulator with the default 
setting of the switch’s serial port. With this, you can communicate with the switch.  
In the switch, RS-232 interface only supports baud rate 57.6k bps with 8 data 
bits, 1 stop bit, no parity check and no flow control. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
To configure the switch, please follow the procedures below: 
1. 
Find the RS-232 DB-9 cable with female DB-9 connector bundled. 
Normally, it just uses pins 2, 3 and 7. See also Appendix B for more 
details on Null Modem Cable Specifications. 
2. 
Attaches the DB-9 female cable connector to the male serial RS-232 
DB-9 connector on the switch. 
3. 
Attaches the other end of the serial RS-232 DB-9 cable to PC’s serial 
port, running a terminal emulator supporting VT100/ANSI terminal with 
The switch’s serial port default settings.  For example, 
Windows98/2000/XP HyperTerminal utility. 
Note: The switch’s serial port default settings are listed as follows:  
Baud rate 
 
 
 
              57600   
Stop 
bits 
     
Data bits 
 
 
 
 
 8 
Parity 
 
 
 
 
 N 
Flow 
control 
     
none 
4. 
When you complete the connection, then press <Enter> key. The login 
prompt will be shown on the screen. The default username and 
password are shown as below: 
Username = admin                 Password = admin 
GSW-0890 L2 Managed Switch  
Default IP Setting: 
IP address = 192.168.1.1 
Subnet Mask = 255.255.255.0 
Default Gateway = 192.168.1.254 
 
Terminal or Terminal Emulator
Fig. 2-7 
RS-232 cable with female  
DB-9 connector at both ends
 
 RS-232 
AC Line 100-240V 50/60 Hz 
RS-232 DB-9 Connector