Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007
Installing the Server Into the Slide Rail 
Assemblies
Use this procedure to install the server chassis, with mounting brackets, into the 
slide-rail assemblies that are mounted to the rack.
Caution – 
This procedure requires a minimum of two people because of the weight 
of the server. Attempting this procedure alone could result in equipment damage or 
personal injury.
1. Push the slide-rails into the slide-rail assemblies as far as possible.
2. Raise the server so that the rear ends of the mounting brackets are aligned with 
the slide-rail assemblies that are mounted in the equipment rack. See 
3. Insert the mounting brackets into the slide-rails, then push the server into the 
rack until the mounting brackets encounter the slide-rail stops (approximately 12 
inches or 30 cm). 
FIGURE 1-4 
Inserting the Server With Mounting Brackets Into the Slide-Rails
Slide-rail
assembly
mounted on
rack post
Mounting bracket
inserted into
slide-rail
Slide-rail
release button
Slide-rail locks