After the unit is connected to power it will automatically begin 
operating. With the doors closed, the temperature of the 
cabinet should reach 36°F to 40°F (2°C to 4°C) on refrigerators 
in about one hour. 
A thermostat located in the evaporator housing on interior rear 
of the unit, controls the temperature in the box. The factory 
setting for the control is “4” and maintains about 38°F (3°C) 
in the box. Set toward “1” for higher temperatures and toward 
“7” for lower temperatures.
Continuous opening and closing of the doors will hamper the 
unit’s ability to maintain optimum refrigeration temperature.
Refrigerators defrost automatically with every cycle of the 
compressor. The water generated is routed to a pan on the 
rear of the unit and is evaporated by the heat given off by the 
compressor.
Service Alert
During normal operation the evaporator fan may cycle 
and/or pulse independently of the compressor. Consult 
the service manual or contact Technical Support at 
1-888-732-2446 if you are unsure of the proper function.
Refrigerator Temperature Control Operation
Cooling Cycle
Defrost Cycle
Compressor On
Compressor Off
Compressor Off
Evap Fan 
On
Evap Fan 
Off
Evap Fan 
On
Evap Fan 
Off
Evap Fan 
On
Evap Fan 
Off