Intel SERVER CHASSIS SR2500 SR2500 Benutzerhandbuch
Produktcode
SR2500
Peripheral and Hard Drive Sub-System
Intel® Server System SR2500AL
Revision – 1.00
Intel order number D31980-004
54
5.5.2.1
Enclosure Management Controller
The backplane utilizes the features of the Vitesse* VSC410 to implement several enclosure
management functions. The chip provides in-band SAF-TE and SES management and utilizes
the four I
management functions. The chip provides in-band SAF-TE and SES management and utilizes
the four I
2
C interfaces listed below.
1. I2C bus 0 is connected to an EEPROM which stores configuration and FRU data
2. I2C bus 1 is connected to an LM75 temperature sensor
3. I2C bus 2 is connected to an IPMB bus from the server board.
4. I2C bus 3 is connected to the LSISAS1068 SAS controller.
5.5.2.2
Hard Drive Activity and Fault LEDs
The backplanes support an activity/fault LED for each of the hard drive connectors. The LED will
illuminate green for activity or amber for a drive fault. The green activity LED is driven by the
SAS/SATA hard disk drive directly. The amber fault LED is driven by the VSC410*
management controller whenever a fault condition is detected. When the drive is used in a
RAID configuration, the RAID controller will have control over the fault LED and it may exhibit
different behavior.
illuminate green for activity or amber for a drive fault. The green activity LED is driven by the
SAS/SATA hard disk drive directly. The amber fault LED is driven by the VSC410*
management controller whenever a fault condition is detected. When the drive is used in a
RAID configuration, the RAID controller will have control over the fault LED and it may exhibit
different behavior.
Table 40. Hard Drive LED Function Definitions
Status LED
Definition
GREEN HDD
Activity
AMBER HDD
Fail