Peripheral and Hard Drive Sub-System 
Intel® Server System SR2500AL 
 
 
Revision – 1.00 
Intel order number D31980-004 
54 
 
5.5.2.1 
Enclosure Management Controller 
The backplane utilizes the features of the Vitesse* VSC410 to implement several enclosure 
management functions.  The chip provides in-band SAF-TE and SES management and utilizes 
the four I
2
C interfaces listed below.  
1.  I2C bus 0 is connected to an EEPROM which stores configuration and FRU data 
2.  I2C bus 1 is connected to an LM75 temperature sensor 
3.  I2C bus 2 is connected to an IPMB bus from the server board. 
4.  I2C bus 3 is connected to the LSISAS1068 SAS controller. 
5.5.2.2 
Hard Drive Activity and Fault LEDs 
The backplanes support an activity/fault LED for each of the hard drive connectors. The LED will 
illuminate green for activity or amber for a drive fault.  The green activity LED is driven by the 
SAS/SATA hard disk drive directly.  The amber fault LED is driven by the VSC410* 
management controller whenever a fault condition is detected.  When the drive is used in a 
RAID configuration, the RAID controller will have control over the fault LED and it may exhibit 
different behavior.  
Table 40. Hard Drive LED Function Definitions 
Status LED 
Definition 
GREEN HDD 
Activity 
AMBER HDD 
Fail