Southbend SB1055F 16" X 60" w/DRO Benutzerhandbuch

Seite von 136
For Machines Mfg. Since 3/11
16-Speed Gearhead Lathe
-31-
P R E P A R A T I O N
17.  Move the spindle ON/OFF lever to the OFF 
(middle) position, reset the STOP button by 
twisting it clockwise until it pops out, then 
restart spindle rotation.
18.  Push the foot brake. The lathe should come 
to a quick stop.
— If the brake pedal has no effect on the 
lathe, push the STOP button, and refer to 
the Brake & Switch subsection on Page 
80 to make any required adjustments.
  After verifying the brake works correctly, 
continue with the next step.
19.  Move the spindle ON/OFF lever to the OFF 
(middle) position. Remove the lathe end gear 
cover. This trips a safety switch that should 
prevent the lathe from starting while the 
cover is removed.
20.  Stand away from all the exposed gears on 
the side of the headstock, and attempt to 
start the lathe.
— If the lathe starts with the end gear 
cover removed, the safety switch is not 
operating correctly. This safety feature 
must operate properly before continuing. 
Press the STOP button to turn the lathe 
OFF, disconnect the lathe from power, 
and call Tech Support for help.
21.  Push the STOP button in, move the spindle 
ON/OFF lever to the OFF position, then 
replace the end gear cover.
22.  Lift the chuck guard up—this will activate 
the chuck guard safety switch. Reset the 
STOP button and attempt to start the lathe.
— If the lathe starts with the chuck guard 
in the up position, the safety switch is not 
operating correctly. This safety feature 
must operate properly before continuing. 
Press the STOP button to turn the lathe 
OFF, disconnect it from power, and call 
Tech Support for help.
23.
  Point the coolant nozzle down into the chip 
drawer and verify that there is coolant in the 
reservoir (refer to Coolant System Service 
on Page 72 for detailed instructions).
24.  Re-start the lathe, use the coolant pump 
switch on the control panel to start the 
pump, then open the valve. Verify that the 
coolant flows from the nozzle, then close the 
valve and turn the pump OFF.
Congratulations! The test run is complete. Turn 
the lathe OFF and perform the Spindle Break-
In procedure on the next page.
After the first 16 hours of use, the V-belts will 
stretch and seat into the pulley grooves. The 
V-belts must be properly re-tensioned after 
this period to avoid reducing their useful life. 
Refer to the V-Belts subsection on Page 80 
for detailed instructions.