16-Speed Gearhead Lathe
E L E C T R I C A L
Correcting Phase 
Polarity Wiring
This sub-section is only provided for 
troubleshooting. If you discover during the test 
run that the lathe will not operate, or that the 
spindle runs backwards, the lathe may be wired 
out of phase. Without the proper test equipment 
to determine the phase of power source legs, 
wiring machinery to 3-phase power may require 
trial-and-error. Correcting this is simply a 
matter of reversing the positions where two of 
the incoming power source wires are connected.
To correct wiring that is out of phase:
1.  Push the STOP button, turn the master 
power switch to OFF, and disconnect the 
machine from power.
2.  Open the electrical box and swap any two hot 
wires coming from the plug, as illustrated in 
Figure 148.
3.  Close and latch the electrical box, and 
reconnect the machine to the power source.
Swap any two
of these wires
L3
L2
L1
To Power 
Supply
Hot
MASTER 
POWER SWITCH
Hot
Hot
Ground
Figure 148. Swapping L1 and L2 power connections 
to correct out-of-phase wiring.