Troubleshooting Guide 
Trouble 
Probable Cause 
Solution 
Couplers are not securely attached to 
the tool or pump 
Check the Coupler connections and make 
certain that they are connected. 
Coupler is defective 
Replace any defective Coupler. 
Defective remote control switch 
Replace the switch and/or control pendent 
Piston will not advance or 
retract 
Dirt in the direction-control valve of 
the pump unit 
Disassemble the pump and clean the 
direction-control valve. 
Hose connections reversed 
Make certain the advance on the pump is 
connected to the advance on the tool and 
retract on the pump is connected to the 
retract on the tool. 
Retract hose not connected 
Connect the retract hose securely 
Piston will not retract 
Retract pin and/or Spring broken 
Replace the broken pin and/or spring 
Piston Seal and/or End Plug Seal 
leaking 
Replace any defective O-rings 
Retaining Screws sheared 
Replace any broken screws. 
Cylinder will not build up 
pressure 
Coupler is defective 
Replace any defective Coupler 
Grease or dirt build up in the teeth of 
the Ratchet and Segment Pawl 
Disassemble the Ratchet and clean the 
grease or dirt out of the teeth 
Ratchet will not turn 
Worn or broken teeth on Ratchet an/or 
Segment Pawl 
Replace any worn or damaged parts 
Tool tightens immediately 
when turned on 
Hose connections are reversed 
Depress the advance button to release the 
tool; shut the pump off in the advance 
position and reverse the hose connection 
Defective relief valve 
Inspect, adjust or replace the relief valve 
Air supply too low or air hose too small 
Make certain the air supply and hose size 
comply with the pump manual 
recommendations. 
Electric power source is too low 
Make certain the amperage, voltage and 
any extension cord size comply with the 
pump manual requirements 
Defective Gauge 
Replace the Gauge 
Low oil level 
Check and fill the pump reservoir 
Pump will not build up 
pressure 
Clogged filter 
Inspect, clean and/or replace the pump 
filter 
Pressure reading erratic 
Defective Gauge 
Replace the Gauge 
Nut Returns with retract 
stroke 
Ball Plungers are not engaging the 
Drive Sleeves 
Thread the Ball Plungers to the correct 
depth in the Housing. 