Jenn-Air W10197059B Benutzerhandbuch

Seite von 24
10
Install Cooktop
1. Using 2 or more people, place cooktop right side up into the 
cutout.
NOTE: Make sure that the front edge of the cooktop is parallel 
to the front edge of the countertop. If repositioning is needed, 
lift entire cooktop up from the cutout to avoid scratching the 
countertop.
2. For island or peninsula installations, go to “Rotate Blower - 
Optional” section.
3. Connect blower exhaust scroll to ducting.
4. Use vent clamps to secure the ducting to the blower exhaust 
scroll.
5. Reinstall removable grease filter.
6. Reinstall vent grille.
Make Electrical Connection
This cooktop is manufactured with the frame connected to the 
bare ground wire. Connect the cooktop cable to the junction box 
through the UL listed or CSA approved conduit connector.
1. Disconnect power.
2. Remove junction box cover, if present.
3. Connect the flexible cable conduit from the cooktop to the 
junction box using a UL listed or CSA approved conduit 
connector.
4. Tighten screws on conduit connector if present.
5. See “Electrical Connection Options Chart” to complete 
installation for your type of electrical connection.
Electrical Connection Options
4-Wire Cable from Home Power Supply to 4-Wire Cable 
from Cooktop 
IMPORTANT: Use the 4-wire cable from home power supply in 
the U.S. where local codes do not allow grounding through 
neutral, New Branch circuit installations (1996 NEC), mobile 
homes and recreational vehicles, new construction, and in 
Canada.
1. Connect the 2 black wires together using the UL listed wire 
connectors.
2. Connect the 2 red wires together using the UL listed wire 
connectors.
3. Connect the 2 white wires together using the UL listed wire 
connectors.
4. Connect the green (or bare) ground wire from the cooktop 
cable to the green (or bare) ground wire (in the junction box) 
using the UL listed wire connectors.
5. Install junction box cover.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
If your home has:
And you will be 
connecting to:
Go to Section:
4-wire
A fused 
disconnect or 
circuit breaker 
box
4-Wire Cable from 
Power Supply 
3-wire
A fused 
disconnect or 
circuit breaker 
box
3-Wire Cable from 
Power Supply 
A. Cable from home power supply
B. Black wires
C. Bare ground wires
D. 4-wire cable from cooktop
E. Junction box
F. White wires
G. UL listed wire connector
H. Red wires
I. UL listed or CSA approved 
conduit connector
½"
(1.3 cm)
½"
(1.3 cm)
A
B
C
D
E
F
G
H
I