Keating Of Chicago 2006 Benutzerhandbuch

Seite von 43
14
Problem
Probable Cause
Solution
Basket-lift motor runs, but basket
does not move.
a. Actuator is faulty.
a. Replace actuator.
Basket(s) rise prematurely.
a. Electronic timer is faulty.
b. Basket lift relay is faulty.
a. Replace timer.
b. Replace relay.
Spark module flashing.
a. Steady OFF.
b. Steady ON.
c. 1 Flash.
d. 2 Flashes.
e. 3 Flashes.
f. 4 Flashers.
g. 5 Flashes.
a. NO Power or Control Hardware 
Fault.
b. Power Applied; Control Okay.
c. No flame sense (current trial 
only). Active until flame sense on 
next trial.
d. Marginal flame between 1.5mkA
and 0.5mkA.
e. Ignition lockout; too many ignition 
failures:
1. Turn off unit.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
f. Ignition lockout; too many flame 
losses:
1. Turn off unit.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
g. Control hardware fault detected.