Keating Of Chicago 2006 ユーザーズマニュアル
14
Problem
Probable Cause
Solution
Basket-lift motor runs, but basket
does not move.
does not move.
a. Actuator is faulty.
a. Replace actuator.
Basket(s) rise prematurely.
a. Electronic timer is faulty.
b. Basket lift relay is faulty.
a. Replace timer.
b. Replace relay.
Spark module flashing.
a. Steady OFF.
b. Steady ON.
c. 1 Flash.
d. 2 Flashes.
e. 3 Flashes.
f. 4 Flashers.
g. 5 Flashes.
a. NO Power or Control Hardware
Fault.
b. Power Applied; Control Okay.
c. No flame sense (current trial
only). Active until flame sense on
next trial.
next trial.
d. Marginal flame between 1.5mkA
and 0.5mkA.
e. Ignition lockout; too many ignition
failures:
1. Turn off unit.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
f. Ignition lockout; too many flame
losses:
1. Turn off unit.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
2. Check incoming gas.
3. Spark at electrode.
4. Electrode.
g. Control hardware fault detected.