8. Thread electrical from the inside of the unit through the 
supplied hole in the top. Do not cut another hole to thread 
electrical. 
9. Thread electrical wires through the top of control box and 
connect to controls.  
• Attach labeled electrical line to the corresponding labeled 
connector on the control panel.
10. Pipe remote condensing unit to the refrigerant lines 
coming out of the top of the cabinet.  
This should be done by a qualified refrigeration expert.
Put the compressor system in a suitable, well aired place no 
farther than 25 feet. from cabinet. 
11. Place interior probes
 
1. Interior Probe1: Place on wall next to the evaporator
 
2. Food Probe: Place in food product for monitoring
 
3. Interior Probe2: Place on opposite side of cabinet 
 
from evaporator 3/4 of the way to the top of the 
 
cabinet.
12. Unit must be plumbed with a P-trap to a drain for 
evaporator water discharge.
13. Place cam plugs in all cam holes to cover them.  Press until 
seated in holes.
14. Install ramp and threshold onto the front of the outside of 
the door.