Hoshizaki DT-400BAH-OS Benutzerhandbuch

Seite von 21
17
 
 
 
Fig. 8 
 
 
 
 
 
 
 
Fig. 9
B. Cleaning and Sanitizing Instructions - Dispensing Components
Perform following the cleaning and sanitizing procedures for the water system.
1. Cleaning Solution
Dilute approximately 9.6 fl. oz. (0.29 l) of recommended cleaner, Hoshizaki "Scale Away" 
or "LIME-A-WAY" (Economics Laboratory, Inc.), with 1.6 gallons (6.0 l) of warm water.
2. Sanitizing Solution
 Dilute approximately 0.82 fl. oz. (25 ml) of a 5.25% sodium hypochlorite solution 
(chlorine bleach) with 1.6 gallons (6.0 l) of warm water.
3. Dispensing Components Cleaning and Sanitizing Procedure
1) Move the control switch to the "OFF" position and remove the upper front and  top 
panels.
2) Move the power switch to the "OFF" position. Unplug the icemaker from the electrical 
outlet.
3) Remove the front cover of the storage bin
4) Remove the thumbscrews, first from the vertical plane and then from the horizontal 
plane of the motor brackets. Move the agitating motor and the dispensing motor 
towards you. Then remove the agitator and the auger (ice dispensing). See Fig. 7.
Fig. 7
5) Remove the bin control bracket assembly. See Fig. 8.
6) Remove the snap pin, shaft and actuator.
7) Remove the thumbscrews, spout and packing. See Fig 9.