Hoshizaki KM-2500SWH3 Benutzerhandbuch

Seite von 61
36
Problem
Possible Cause
Remedy
[1] The icemaker will not 
start. (continued)
h) Control Transformer
1. Coil winding open or 
shorted.
1. Replace.
i) Wiring to Control Board 1. Loose connections or 
open.
1. Check for continuity and 
replace.
j) Interlock Switch  
(Cleaning Valve)
1. Open position.
1. Move to closed position.
2. Bad contacts.
2. Check for continuity and 
replace.
k) Thermistor
1. Leads shorted or open 
and high temperature 
or harvest backup 
timer safety operates 
(1 beep or 2 beep 
alarm).
1. See "IV.E. Thermistor 
Check."
l) Hot Gas Valve
1. Continues to open 
in freeze cycle and 
freeze timer safety 
operates (3 beep 
alarm). 
1. Check for hot gas valve 
stuck open and replace. 
m)Inlet Water Valve
1. Mesh filter or orifice 
gets clogged and 
water supply cycle 
does not finish.
1. Clean.
2. Coil winding open.
2. Replace.
3. Wiring to inlet water 
valve.
3. Check for loose 
connection or open, and 
replace.
n) Float Switch
1. Bad contacts.
1. Check for continuity and 
replace.
2. Float does not move 
freely.
2. Clean or replace.
o) Control Board
1. Defective or in alarm. 1. See "IV.B. Control Board 
Check."
[2] Fill cycle will not 
terminate.
a) Water Supply
1. Water supply off or 
pressure too low.
1. Check and get 
recommended pressure.
b) Float Switch
1. Connector 
disconnected.
1. Reconnect.
2. Defective switch.
2. Check and replace.
3. Float does not move 
freely.
3. See "IV.D. Float Switch 
Check and Cleaning."
c) Control Board
1. Defective.
1. See "IV.B. Control Board 
Check."
[3] Compressor will 
not start or stops 
operating.
a) Magnetic Contactor
1. Bad contacts.
1. Check for continuity and 
replace.
2. Coil winding open.
2. Replace.
b) Start Capacitor or Run 
Capacitor
1. Defective.
1. Replace.