The condensing unit must be positioned in a permanent site under the following guidelines:
• A firm and flat site.
• A dry and well ventilated area with 24" (61 cm) clearance in both front and rear for proper 
air circulation and ease of maintenance and/or service should they be required. See 
Fig. 1.
• The maximum line length is 55 feet.  
Note: If the recommended guidelines of the installation are exceeded, the icemaker 
performance may be reduced. 
CAUTION
Failure to install the equipment within these guidelines may adversely affect
performance, component life, and warranty coverage.
2. Condensing Unit
IMPORTANT
This condensing unit is intended for outdoor use. Normal operating ambient 
temperature should be within -20°F  to +122°F (-29°C to 50°C). Operation of 
the unit, for extended periods, outside of these normal temperature ranges may 
affect icemaker performance.
The icemaker must be coupled with the appropriate condensing unit as listed below.
Air
Air
Minimum " (1 cm) Clearance
Fig. 1
Icemaker
Hoshizaki Condensing Unit
KMS-100MLH
SRK-1H/