Hoshizaki KM-320MWH Benutzerhandbuch

Seite von 50
8
IV. Service Diagnosis
A. No Ice Production
Problem
Possible Cause
Remedy
[1] The icemaker will not 
start.
a)Power Supply
1. OFF position.
1. Move to ON position.
. Loose connection.
. Tighten.
3. Bad contacts.
3. Check for continuity and 
replace.
4. Voltage too high.
4. Check and get 
recommended voltage.
b)Fuse (Inside fused 
disconnect, if any)
1. Blown.
1. Check for short circuit and 
replace.
c) Control Switch
1. OFF position.
1. Move to ICE position.
. Bad contacts.
. Check for continuity and 
replace.
d)Bin Control Thermostat 1. Tripped with bin filled 
with ice.
1. Remove ice.
. Ambient temperature 
too cool.
. Increase ambient 
temperature.
3. Set too warm.
3. See "II.B.4. Controls 
and Adjustments, f) Bin 
Control."
4. Bulb out of position.
4. Place in position.
5. Bad contacts or leaks 
in bulb.
5. Check for continuity and 
replace.
e)High Pressure Control 1. Bad contacts.
1. Check for continuity and 
replace.
f) Transformer
1. Thermal fuse blown or 
coil winding opened.
1. Replace.
g)Wiring to Controller 
Board
1. Loose connections or 
open.
1. Check for continuity and 
replace.
h)Thermistor
1. Leads short-circuit 
or open and high 
temperature safety 
operates.
1. See "II.B.4. Controls and 
Adjustments, a) Defrost 
Control."
i) Hot Gas Solenoid Valve 1. Continues to open in 
freeze cycle and high 
temperature safety 
operates.
1. Check for power off in 
freeze cycle and replace.