Hoshizaki KM-320MWH Benutzerhandbuch

Seite von 50
9
Problem
Possible Cause
Remedy
j) Water Supply Line
1. Water supply off and 
water supply cycle 
does not finish.
1. Check and get 
recommended pressure.
. Condenser water 
pressure too low 
or off and pressure 
control opens and 
closes frequently to 
finally operate high 
temperature safety.
. Check and get 
recommended pressure.
k) Water Solenoid
1. Mesh filter or orifice 
gets clogged and 
water supply cycle 
does not finish.
1. Clean.
. Coil winding opened. . Replace.
3. Wiring to water valve. 3. Check for loose 
connection or open, and 
replace.
l) Controller Board
1. Defective.
1. See "II.B.5. Checking the 
Controller Board."
m)Interlock Switch 
(Cleaning Valve)
1. OFF Position
1. Move to ON position.
. Bad contacts.
. Check for continuity and 
replace.
[] Water continues to 
be supplied, and the 
icemaker will not 
start.
a)Float Switch
1. Connector 
disconnected.
1. Place in position.
. Leads opened or 
defective switch.
. Check and replace.
3. Float does not move 
freely.
3. Clean or replace.
b)Controller Board
1. Defective.
1. Replace.
c) Contactor
1. Open coil or contacts 
worn.
1. Replace.
[3] Compressor will 
not start or stops 
operating.
a)Wash Switch
1. WASH position.
1. Move to ICE position.
. Bad contacts.
. Check and replace.
b)High Pressure 
Controller
1. Dirty air filter or 
condenser.
1. Clean.
. Ambient or condenser 
water temperature too 
warm.
. Reduce temperature.
3. Refrigerant 
overcharged.
3. Recharge.
4. Condenser water 
pressure too low or off. 
(water-cooled model)
4. Check and get 
recommended pressure.
5. Fan not operating. 
(except water-cooled 
model)
5. See chart A.[6]
6. Refrigerant line or 
components plugged.
6. Clean and replace drier.